Технические данные (бумага) | 6ES7 211-0AA23-0XB0 | 6ES7 211-0BA23-0XB0 | 6ES7 212-1AB23-0XB0 | 6ES7 212-1BB23-0XB0 | Supply voltages | | | | | Rated value | | | | | | Yes | | Yes | | - permissible range, lower limit (DC)
| 20.4 V | | 20.4 V | | - permissible range, upper limit (DC)
| 28.8 V | | 28.8 V | | | | Yes | | Yes | | | Yes | | Yes | - permissible range, lower limit (AC)
| | 85 V | | 85 V | - permissible range, upper limit (AC)
| | 264 V | | 264 V | - permissible frequency range, lower limit
| | 47 Hz | | 47 Hz | - permissible frequency range, upper limit
| | 63 Hz | | 63 Hz | Voltages and currents | | | | | Load voltage L+ | | | | | | 24 V | 24 V | 24 V | 24 V | - permissible range, lower limit (DC)
| 20.4 V | 5 V | 20.4 V | 5 V | - permissible range, upper limit (DC)
| 28.8 V | 30 V | 28.8 V | 30 V | Load voltage L1 | | | | | | | 100 V; 100 to 230 V AC | | 100 V; 100 to 230 V AC | - permissible range, lower limit (AC)
| | 5 V | | 5 V | - permissible range, upper limit (AC)
| | 250 V | | 250 V | - permissible frequency range, lower limit
| | 47 Hz | | 47 Hz | - permissible frequency range, upper limit
| | 63 Hz | | 63 Hz | Current consumption | | | | | | 10 A; at 28.8 V | 20 A; at 264 V | 10 A; at 28.8 V | 20 A; at 264 V | - from supply voltage L+, max.
| 450 mA; 80 to 450 mA | | 500 mA; 85 to 500 mA, output current for expansion modules (5 V DC) 340 mA | | - from supply voltage L1, max.
| | 120 mA; 15 to 60 mA (240 V), 30 to 120 mA (120 V); output current for expansion modules (5 V DC) 340 mA | | 140 mA; 20 to 70 mA (240 V), 40 to 140 mA (120 V); output current for expansion modules (5 V DC) 340 mA | back-up battery | | | | | | 50 h; (min. 8 h at 40 °C); 200 days (typ.) with optional battery module | 50 h; (min. 8 h at 40 °C); 200 days (typ.) with optional battery module | 50 h; (min. 8 h at 40 °C); 200 days (typ.) with optional battery module | 50 h; (min. 8 h at 40 °C); 200 days (typ.) with optional battery module | Memory/backup | | | | | Memory | | | | | - Number of memory modules (optional)
| 1; pluggable memory module, content identical to integral EEPROM, in addition, recipes, data logs and other files can be saved. | 1; pluggable memory module, content identical to integral EEPROM, in addition, recipes, data logs and other files can be saved. | 1; pluggable memory module, content identical to integral EEPROM, in addition, recipes, data logs and other files can be saved. | 1; pluggable memory module, content identical to integral EEPROM, in addition, recipes, data logs and other files can be saved. | - Data memory and program memory
| | | | | | 2 KByte | 2 KByte | 2 KByte | 2 KByte | | 4 KByte | 4 KByte | 4 KByte | 4 KByte | Backup | | | | | | Yes; Program: entire program maintenance-free in integral EEPROM, programmable via CPU; data: entire DB 1 loaded from PG/PC maintenance-free in integral EEPROM, current values of DB 1 in RAM, retentive flags, timers, counters etc., maintenance free via super capacitor; optional battery | Yes; Program: entire program maintenance-free in integral EEPROM, programmable via CPU; data: entire DB 1 loaded from PG/PC maintenance-free in integral EEPROM, current values of DB 1 in RAM, retentive flags, timers, counters etc., maintenance free via super capacitor; optional battery | Yes; Program: entire program maintenance-free in integral EEPROM, programmable via CPU; data: entire DB 1 loaded from PG/PC maintenance-free in integral EEPROM, current values of DB 1 in RAM, retentive flags, timers, counters etc., maintenance free via super capacitor; optional battery | Yes; Program: entire program maintenance-free in integral EEPROM, programmable via CPU; data: entire DB 1 loaded from PG/PC maintenance-free in integral EEPROM, current values of DB 1 in RAM, retentive flags, timers, counters etc., maintenance free via super capacitor; optional battery | CPU/processing times | | | | | - for bit instruction, max.
| 0.22 µs | 0.22 µs | 0.22 µs | 0.22 µs | Timers/counters and their retentive characteristics | | | | | S7 counter | | | | | | 256 | 256 | 256 | 256 | - of which retentive with battery
| | | | | | Yes; via super capacitor or battery | Yes; via super capacitor or battery | Yes; via super capacitor or battery | Yes; via super capacitor or battery | | 1 | 1 | 1 | 1 | | 256 | 256 | 256 | 256 | | | | | | | 0 | 0 | 0 | 0 | | 32,767 | 32,767 | 32,767 | 32,767 | S7 times | | | | | | 256 | 256 | 256 | 256 | - of which retentive with battery
| | | | | | Yes; via super capacitor or battery | Yes; via super capacitor or battery | Yes; via super capacitor or battery | Yes; via super capacitor or battery | | 64 | 64 | 64 | 64 | | | | | | | 1 ms | 1 ms | 1 ms | 1 ms | | 54 min; 4 times, 1 ms to 30 s 16 times, 10 ms to 5 min 236 times, 100 ms to 54 min | 54 min; 4 times, 1 ms to 30 s 16 times, 10 ms to 5 min 236 times, 100 ms to 54 min | 54 min; 4 times, 1 ms to 30 s 16 times, 10 ms to 5 min 236 times, 100 ms to 54 min | 54 min; 4 times, 1 ms to 30 s 16 times, 10 ms to 5 min 236 times, 100 ms to 54 min | Data areas and their retentive characteristics | | | | | Flags | | | | | | 32 Byte | 32 Byte | 32 Byte | 32 Byte | | Yes; M0.0 to M31.7 | Yes; M0.0 to M31.7 | Yes; M0.0 to M31.7 | Yes; M0.0 to M31.7 | - of which retentive with battery
| 0 to 255, via super capacitor or battery, adjustable | 0 to 255, via super capacitor or battery, adjustable | 0 to 255, via super capacitor or battery, adjustable | 0 to 255, via super capacitor or battery, adjustable | - of which retentive without battery
| 0 to 112 in EEPROM, adjustable | 0 to 112 in EEPROM, adjustable | 0 to 112 in EEPROM, adjustable | 0 to 112 in EEPROM, adjustable | Configuration | | | | | - Connectable programming devices/PCs
| SIMATIC PG/PC, Standard PC | SIMATIC PG/PC, Standard PC | SIMATIC PG/PC, Standard PC | SIMATIC PG/PC, Standard PC | - Central units/expansion units, max.
| | | 2 expansion modules. Only expansion modules of the S7-22x series can be used. Because of the limited output current, the use of expansion modules may be subject to restrictions. | 2 expansion modules. Only expansion modules of the S7-22x series can be used (because of the limited output current, the use of expansion modules may be subject to restrictions.) | I/O expansions | | | | | - Analog inputs/outputs, max.
| | | 10; max. 8 inputs and 2 outputs (EM) or max. 0 inputs and 4 outputs (EM) | 10; max. 8 inputs and 2 outputs (EM) or max. 0 inputs and 4 outputs (EM) | - Digital inputs/outputs, max.
| | | 78; max. 40 inputs and 38 outputs (CPU+EM) | 78; max. 40 inputs and 38 outputs (CPU+EM) | - AS interface inputs/outputs, max.
| | | 31; AS interface slaves (CP 243-2) | 31; AS interface slaves (CP 243-2) | Connection system | | | | | | No | No | No | No | 1st interface | | | | | | integrated RS 485 interface | integrated RS 485 interface | integrated RS 485 interface | integrated RS 485 interface | | RS 485 | RS 485 | RS 485 | RS 485 | Functionality | | | | | | Yes; as MPI Slave for data exchange with MPI Masters (S7-300/S7-400-CPUs, OPs, TDs, Push Button Panels); internal S7-200 CPU/CPU communication is limited in the MPI network; transmission rates 19.2/187.5 kbit/s | Yes; as MPI Slave for data exchange with MPI Masters (S7-300/S7-400-CPUs, OPs, TDs, Push Button Panels); internal S7-200 CPU/CPU communication is limited in the MPI network; transmission rates 19.2/187.5 kbit/s | Yes; as MPI Slave for data exchange with MPI Masters (S7-300/S7-400-CPUs, OPs, TDs, Push Button Panels); internal S7-200 CPU/CPU communication is limited in the MPI network; transmission rates 19.2/187.5 kbit/s | Yes; as MPI Slave for data exchange with MPI Masters (S7-300/S7-400-CPUs, OPs, TDs, Push Button Panels); internal S7-200 CPU/CPU communication is limited in the MPI network; transmission rates 19.2/187.5 kbit/s | | Yes; with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200 internal CPU/CPU communication; transmission rates 9.6/19.2/187.5 kbit/s | Yes; with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200 internal CPU/CPU communication; transmission rates 9.6/19.2/187.5 kbit/s | Yes; with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200 internal CPU/CPU communication; transmission rates 9.6/19.2/187.5 kbit/s | Yes; with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200 internal CPU/CPU communication; transmission rates 9.6/19.2/187.5 kbit/s | | Yes; as a freely programmable interface with an interrupt option for serial data transmission with external units with ASCII ptotocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4 kbit/s; at 1.2 to 38.4 kbit/s, the PC/PPI cable can be used as an RS232/RS485 converter | Yes; as a freely programmable interface with an interrupt option for serial data transmission with external units with ASCII ptotocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4 kbit/s; at 1.2 to 38.4 kbit/s, the PC/PPI cable can be used as an RS232/RS485 converter | Yes; as a freely programmable interface with an interrupt option for serial data transmission with external units with ASCII ptotocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4 kbit/s; at 1.2 to 38.4 kbit/s, the PC/PPI cable can be used as an RS232/RS485 converter | Yes; as a freely programmable interface with an interrupt option for serial data transmission with external units with ASCII ptotocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4 kbit/s; at 1.2 to 38.4 kbit/s, the PC/PPI cable can be used as an RS232/RS485 converter | MPI | | | | | | 187.5 kBit/s | 187.5 kBit/s | 187.5 kBit/s | 187.5 kBit/s | | 19.2 kBit/s | 19.2 kBit/s | 19.2 kBit/s | 19.2 kBit/s | CPU/ programming | | | | | Programming language | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Bit logic instructions, compare instructions, timer instructions, counter instructions, clock instructions, integer math instructions, floating-point math instructions, numeric functions, move instructions, table instructions, logic instructions, shift and rotate instructions, conversion instructions, program control instructions, interrupt and communications instructions, logic stack instructions | Bit logic instructions, compare instructions, timer instructions, counter instructions, clock instructions, integer math instructions, floating-point math instructions, numeric functions, move instructions, table instructions, logic instructions, shift and rotate instructions, conversion instructions, program control instructions, interrupt and communications instructions, logic stack instructions | Bit logic instructions, compare instructions, timer instructions, counter instructions, clock instructions, integer math instructions, floating-point math instructions, numeric functions, move instructions, table instructions, logic instructions, shift and rotate instructions, conversion instructions, program control instructions, interrupt and communications instructions, logic stack instructions | Bit logic instructions, compare instructions, timer instructions, counter instructions, clock instructions, integer math instructions, floating-point math instructions, numeric functions, move instructions, table instructions, logic instructions, shift and rotate instructions, conversion instructions, program control instructions, interrupt and communications instructions, logic stack instructions | - User program protection/password protection
| Yes; 3-stage password protection | Yes; 3-stage password protection | Yes; 3-stage password protection | Yes; 3-stage password protection | | free cycle (OB 1), interrupt-driven, time-driven (1 to 255 ms) | free cycle (OB 1), interrupt-driven, time-driven (1 to 255 ms) | free cycle (OB 1), interrupt-driven, time-driven (1 to 255 ms) | free cycle (OB 1), interrupt-driven, time-driven (1 to 255 ms) | | 1 OB, 1 DB, 1 SDB subprograms with/without parameter transfer | 1 OB, 1 DB, 1 SDB subprograms with/without parameter transfer | 1 OB, 1 DB, 1 SDB subprograms with/without parameter transfer | 1 OB, 1 DB, 1 SDB subprograms with/without parameter transfer | - Number of sub-programs, max.
| 64 | 64 | 64 | 64 | Digital inputs | | | | | | 6; integrated | 6; integrated | 8 | 8 | Length of cable | | | | | - Length of cable shielded, max
| 500 m; Standard input: 500m, fast counters: 50m | 500 m; Standard input: 500m, fast counters: 50m | 500 m; Standard input: 500m, fast counters: 50m | 500 m; Standard input: 500m, fast counters: 50m | - Length of cable unshielded, max
| 300 m; not for high-speed signals | 300 m; not for high-speed signals | 300 m; not for high-speed signals | 300 m; not for high-speed signals | | Yes; optional, per group | Yes; optional, per group | Yes; optional, per group | Yes; optional, per group | Input voltage | | | | | | 24 V | 24 V | 24 V | 24 V | | 0 to 5 V | 0 to 5 V | 0 to 5 V | 0 to 5 V | | min. 15 V | min. 15 V | min. 15 V | min. 15 V | Input current | | | | | | 2.5 mA | 2.5 mA | 2.5 mA | 2.5 mA | Input delay (at rated value of the input voltage) | | | | | | | | | | | Yes; all | Yes; all | Yes; all | Yes; all | | 0.2 ms | 0.2 ms | 0.2 ms | 0.2 ms | | 12.8 ms | 12.8 ms | 12.8 ms | 12.8 ms | | | | | | | Yes; I0.0 to I0.3 | Yes; I0.0 to I0.3 | Yes; I0.0 to I0.3 | Yes; I0.0 to I0.3 | - for counters/technological functions
| | | | | | Yes; (E0.0 to E0.5) 30 kHz | Yes; (E0.0 to E0.5) 30 kHz | Yes; (E0.0 to E0.5) 30 kHz | Yes; (E0.0 to E0.5) 30 kHz | Digital outputs | | | | | - Number of digital outputs
| 4; Transistor | 4; Relay | 6; Transistor | 6; Relay | - Length of cable shielded, max.
| 500 m | 500 m | 500 m | 500 m | - Length of cable unshielded, max.
| 150 m | 150 m | 150 m | 150 m | - Short-circuit protection of the output
| No; provided externally | No; provided externally | No; provided externally | No; provided externally | - Limitation of voltage induced on circuit interruption to
| 1 W | | 1 W | | Switching capacity of the outputs | | | | | | 0.75 A | 2 A | 0.75 A | 2 A | | 5 W | 30 W DC, 200 W AC | 5 W | 30 W DC, 200 W AC | Output voltage | | | | | | 20 V DC | L+/L1 | 20 V DC | L+/L1 | Output current | | | | | | 750 mA | 2 A | 750 mA | 2 A | - for 0 signal residual current, max.
| 0.1 mA | 0 mA | 10 μA | 0 mA | Output delay at resistive load | | | | | | 15 µs; of standard outputs, max. (A0.2 to A0.3) 15 µs; of pulse outputs, max. (A0.0 to A0.1) 2 µs | 10 ms; all outputs | 15 µs; of standard outputs, max. (A0.2 to A0.5) 15 µs; of pulse outputs, max. (A0.0 to A0.1) 2 µs | 10 ms; all outputs | | 130 µs; of standard outputs, max. (A0.2 to A0.3) 100 µs; of pulse outputs, max. (A0.0 to A0.1) 10 µs | 10 ms; all outputs | 130 µs; of standard outputs, max. (A0.2 to A0.5) 100 µs; of pulse outputs, max. (A0.0 to A0.1) 10 µs | 10 ms; all outputs | Parallel switching of 2 outputs | | | | | | Yes | No | Yes | No | Switching frequency | | | | | - of pulse outputs, at resistive load, max.
| 20 kHz; A0.0 to A0.1 | | 20 kHz; A0.0 to A0.1 | | Summation current of the outputs (per group) | | | | | | 3 A | 6 A | 4.5 A | 6 A | - horizontal installation, up to 55 °C, max.
| 3 A | 6 A | 4.5 A | 6 A | Relay outputs | | | | | - Number of operating cycles
| | 10,000,000; mechanical 10 million, at rated load voltage 100,000 | | 10,000,000; mechanical 10 million, at rated load voltage 100,000 | Analog inputs | | | | | - Number of analog potentiometers
| 1; Analog potentiometer; resolution 8 bits | 1; Analog potentiometer; resolution 8 bits | 1; Analog potentiometer; resolution 8 bits | 1; Analog potentiometer; resolution 8 bits | Sensor supply | | | | | 24 V - sensor supply | | | | | | Yes; permissible range: 15.4 to 28.8 V | Yes; permissible range: 20.4 to 28.8 V | Yes; permissible range: 15.4 to 28.8 V | Yes; permissible range: 20.4 to 28.8 V | | Yes; electronic at 600 mA | Yes; electronic at 600 mA | Yes; electronic at 600 mA | Yes; electronic at 600 mA | | 180 mA | 180 mA | 180 mA | 180 mA | Sensor | | | | | Connectable encoders | | | | | | Yes | Yes | Yes | Yes | - permissible closed-circuit current (2-wire BEROS), max.
| 1 mA | 1 mA | 1 mA | 1 mA | Integral functions | | | | | | 4; fast counters (each 30 kHz), 32 bits (incl. sign), usable as up/down counter or for connecting 2 incremental encoders with 2 pulse trains offset by 90° (max. 20 kHz (A/B counter)); parameterizable enable and reset input; interrupt options (incl. Call up a sub-program with any content) when the setpoint value is reached; change of count direction etc. | 4; fast counters (each 30 kHz), 32 bits (incl. sign), usable as up/down counter or for connecting 2 incremental encoders with 2 pulse trains offset by 90° (max. 20 kHz (A/B counter)); parameterizable enable and reset input; interrupt options (incl. Call up a sub-program with any content) when the setpoint value is reached; change of count direction etc. | 4; fast counters (each 30 kHz), 32 bits (incl. sign), usable as up/down counter or for connecting 2 incremental encoders with 2 pulse trains offset by 90° (max. 20 kHz (A/B counter)); parameterizable enable and reset input; interrupt options (incl. Call up a sub-program with any content) when the setpoint value is reached; change of count direction etc. | 4; fast counters (each 30 kHz), 32 bits (incl. sign), usable as up/down counter or for connecting 2 incremental encoders with 2 pulse trains offset by 90° (max. 20 kHz (A/B counter)); parameterizable enable and reset input; interrupt options (incl. Call up a sub-program with any content) when the setpoint value is reached; change of count direction etc. | - Count frequency (counters) max.
| 30 kHz | 30 kHz | 30 kHz | 30 kHz | | 4; 4 rising edges and/or 4 falling edges | 4; 4 rising edges and/or 4 falling edges | 4; 4 rising edges and/or 4 falling edges | 4; 4 rising edges and/or 4 falling edges | | 2; fast outputs, 20 kHz, with interrupt option; pulse width and frequency modulation | 2; fast outputs, 20 kHz, with interrupt option; pulse width and frequency modulation | 2; fast outputs, 20 kHz, with interrupt option; pulse width and frequency modulation | 2; fast outputs, 20 kHz, with interrupt option; pulse width and frequency modulation | - Cut-off frequency (pulse)
| 20 kHz | 20 kHz | 20 kHz | 20 kHz | Potentials/ electrical isolation | | | | | Digital output functions | | | | | | Yes; Optocoupler | Yes; Relay | Yes; Optocoupler | Yes; Relay | - between the channels, in groups of
| 4 | 1 and 3 | 6 | 3 | Digital input functions | | | | | | Yes | Yes | Yes | Yes | - between the channels, in groups of
| 2 and 4 | 2 and 4 | 4 | 4 | Permissible potential difference | | | | | - between different circuits
| 500 V DC between 24 V DC and 5 V DC | 500 V DC between 24 V DC and 5 V DC; 1500 V AC between 24 V DC and 230 V AC | 500 V DC between 24 V DC and 5 V DC | 500 V DC between 24 V DC and 5 V DC; 1500 V AC between 24 V DC and 230 V AC | Environmental requirements | | | | | | For other ambient conditions: see "S7-200 Programmable Controller, System Manual" | For other ambient conditions: see "S7-200 Programmable Controller, System Manual" | For other ambient conditions: see "S7-200 Programmable Controller, System Manual" | For other ambient conditions: see "S7-200 Programmable Controller, System Manual" | Operating temperature | | | | | | 0 °C | 0 °C | 0 °C | 0 °C | | 45 °C | 45 °C | 45 °C | 45 °C | - horizontal mounting, min.
| 0 °C | 0 °C | 0 °C | 0 °C | - horizontal mounting, max.
| 55 °C | 55 °C | 55 °C | 55 °C | Air pressure | | | | | | 860 hPa | 860 hPa | 860 hPa | 860 hPa | | 1,080 hPa | 1,080 hPa | 1,080 hPa | 1,080 hPa | Relative humidity | | | | | | 5 % | 5 % | 5 % | 5 % | | 95 %; RH stressing level 2 in accordance with IEC 1131-2 | 95 %; RH stressing level 2 in accordance with IEC 1131-2 | 95 %; RH stressing level 2 in accordance with IEC 1131-2 | 95 %; RH stressing level 2 in accordance with IEC 1131-2 | Degree of protection and class of protection | | | | | | Yes | Yes | Yes | Yes | Dimensions and weight | | | | | | 270 g | 310 g | 270 g | 310 g | | 90 mm | 90 mm | 90 mm | 90 mm | | 80 mm | 80 mm | 80 mm | 80 mm | | 62 mm | 62 mm | 62 mm | 62 mm | | 6ES7 214-1AD23-0XB0 | 6ES7 214-1BD23-0XB0 | 6ES7 214-2AD23-0XB0 | 6ES7 214-2BD23-0XB0 | 6ES7 216-2AD23-0XB0 | 6ES7 216-2BD23-0XB0 | Supply voltages | | | | | | | Rated value | | | | | | | | Yes | | Yes | | Yes | | - permissible range, lower limit (DC)
| 20.4 V | | 20.4 V | | 20.4 V | | - permissible range, upper limit (DC)
| 28.8 V | | 28.8 V | | 28.8 V | | | | Yes | | Yes | | Yes | | | Yes | | Yes | | Yes | - permissible range, lower limit (AC)
| | 85 V | | 85 V | | 85 V | - permissible range, upper limit (AC)
| | 264 V | | 264 V | | 264 V | - permissible frequency range, lower limit
| | 47 Hz | | 47 Hz | | 47 Hz | - permissible frequency range, upper limit
| | 63 Hz | | 63 Hz | | 63 Hz | Voltages and currents | | | | | | | Load voltage L+ | | | | | | | | 24 V | 24 V | 24 V | 24 V | 24 V | 24 V | - permissible range, lower limit (DC)
| 20.4 V | 5 V | 20.4 V | 5 V | 20.4 V | 5 V | - permissible range, upper limit (DC)
| 28.8 V | 30 V | 28.8 V | 30 V | 28.8 V | 30 V | Load voltage L1 | | | | | | | | | 100 V; 100 to 230 V AC | | 100 V; 100 to 230 V AC | | 100 V; 100 to 230 V AC | - permissible range, lower limit (AC)
| | 5 V | | 5 V | | 5 V | - permissible range, upper limit (AC)
| | 250 V | | 250 V | | 250 V | - permissible frequency range, lower limit
| | 47 Hz | | 47 Hz | | 47 Hz | - permissible frequency range, upper limit
| | 63 Hz | | 63 Hz | | 63 Hz | Current consumption | | | | | | | | 12 A; at 28.8 V | 20 A; at 264 V | 12 A; at 28.8 V | 20 A; at 264 V | 10 A; at 28.8 V | 20 A; at 264 V | - from supply voltage L+, max.
| 700 mA; 110 to 700 mA, output current for expansion modules (5 V DC) 660 mA | | 900 mA; 120 to 900 mA, output current for expansion modules (5 V DC) 660 mA | | 1,050 mA; 150 to 1050 mA, output current for expansion modules (5 V DC) 1000 mA | | - from supply voltage L1, max.
| | 200 mA; 30 to 100 mA (240 V), 60 to 200 mA (120 V); output current for expansion modules (5 V DC) 600 mA | | 220 mA; 35 to 100 mA (240 V), 70 to 220 mA (120 V); output current for expansion modules (5 V DC) 600 mA | | 320 mA; 40 to 160 mA (240 V), 80 to 320 mA (120 V); output current for expansion modules (5 V DC) 1000 mA | back-up battery | | | | | | | | 100 h; (min. 70 h at 40 °C); 200 days (typ.) with optional battery module | 100 h; (min. 70 h at 40 °C); 200 days (typ.) with optional battery module | 100 h; (min. 70 h at 40 °C); 200 days (typ.) with optional battery module | 100 h; (min. 70 h at 40 °C); 200 days (typ.) with optional battery module | 100 h; (min. 70 h at 40 °C); 200 days (typ.) with optional battery module | 100 h; (min. 70 h at 40 °C); 200 days (typ.) with optional battery module | Memory/backup | | | | | | | Memory | | | | | | | - Number of memory modules (optional)
| 1; pluggable memory module, content identical to integral EEPROM, in addition, recipes, data logs and other files can be saved. | 1; pluggable memory module, content identical to integral EEPROM, in addition, recipes, data logs and other files can be saved. | 1; pluggable memory module, content identical to integral EEPROM, in addition, recipes, data logs and other files can be saved. | 1; pluggable memory module, content identical to integral EEPROM, in addition, recipes, data logs and other files can be saved. | 1; pluggable memory module, content identical to integral EEPROM, in addition, recipes, data logs and other files can be saved. | 1; pluggable memory module, content identical to integral EEPROM, in addition, recipes, data logs and other files can be saved. | - Data memory and program memory
| | | | | | | | 8 KByte | 8 KByte | 10 KByte | 10 KByte | 10 KByte | 10 KByte | | 12 KByte; 8 Kbytes for active run-time edit | 12 KByte; 8 Kbytes for active run-time edit | 16 KByte; 12 Kbytes for active run-time edit | 16 KByte; 12 Kbytes for active run-time edit | 24 KByte; 16 Kbytes with active run-time edit | 24 KByte; 16 Kbytes with active run-time edit | Backup | | | | | | | | Yes; Program: entire program maintenance-free in integral EEPROM, programmable via CPU; data: entire DB 1 loaded from PG/PC maintenance-free in integral EEPROM, current values of DB 1 in RAM, retentive flags, timers, counters etc., maintenance free via super capacitor; optional battery | Yes; Program: entire program maintenance-free in integral EEPROM, programmable via CPU; data: entire DB 1 loaded from PG/PC maintenance-free in integral EEPROM, current values of DB 1 in RAM, retentive flags, timers, counters etc., maintenance free via super capacitor; optional battery | Yes; Program: entire program maintenance-free in integral EEPROM, programmable via CPU; data: entire DB 1 loaded from PG/PC maintenance-free in integral EEPROM, current values of DB 1 in RAM, retentive flags, timers, counters etc., maintenance free via super capacitor; optional battery | Yes; Program: entire program maintenance-free in integral EEPROM, programmable via CPU; data: entire DB 1 loaded from PG/PC maintenance-free in integral EEPROM, current values of DB 1 in RAM, retentive flags, timers, counters etc., maintenance free via super capacitor; optional battery | Yes; Program: entire program maintenance-free in integral EEPROM, programmable via CPU; data: entire DB 1 loaded from PG/PC maintenance-free in integral EEPROM, current values of DB 1 in RAM, retentive flags, timers, counters etc., maintenance free via super capacitor; optional battery | Yes; Program: entire program maintenance-free in integral EEPROM, programmable via CPU; data: entire DB 1 loaded from PG/PC maintenance-free in integral EEPROM, current values of DB 1 in RAM, retentive flags, timers, counters etc., maintenance free via super capacitor; optional battery | CPU/processing times | | | | | | | - for bit instruction, max.
| 0.22 µs | 0.22 µs | 0.22 µs | 0.22 µs | 0.22 µs | 0.22 µs | Timers/counters and their retentive characteristics | | | | | | | S7 counter | | | | | | | | 256 | 256 | 256 | 256 | 256 | 256 | - of which retentive with battery
| | | | | | | | Yes; via super capacitor or battery | Yes; via super capacitor or battery | Yes; via super capacitor or battery | Yes; via super capacitor or battery | Yes; via super capacitor or battery | Yes; via super capacitor or battery | | 1 | 1 | 1 | 1 | 1 | 1 | | 256 | 256 | 256 | 256 | 256 | 256 | | | | | | | | | 0 | 0 | 0 | 0 | 0 | 0 | | 32,767 | 32,767 | 32,767 | 32,767 | 32,767 | 32,767 | S7 times | | | | | | | | 256 | 256 | 256 | 256 | 256 | 256 | - of which retentive with battery
| | | | | | | | Yes; via super capacitor or battery | Yes; via super capacitor or battery | Yes; via super capacitor or battery | Yes; via super capacitor or battery | Yes; via super capacitor or battery | Yes; via super capacitor or battery | | 64 | 64 | 64 | 64 | 64 | 64 | | | | | | | | | 1 ms | 1 ms | 1 ms | 1 ms | 1 ms | 1 ms | | 54 min; 4 times, 1 ms to 30 s 16 times, 10 ms to 5 min 236 times, 100 ms to 54 min | 54 min; 4 times, 1 ms to 30 s 16 times, 10 ms to 5 min 236 times, 100 ms to 54 min | 54 min; 4 times, 1 ms to 30 s 16 times, 10 ms to 5 min 236 times, 100 ms to 54 min | 54 min; 4 times, 1 ms to 30 s 16 times, 10 ms to 5 min 236 times, 100 ms to 54 min | 54 min; 4 times, 1 ms to 30 s 16 times, 10 ms to 5 min 236 times, 100 ms to 54 min | 54 min; 4 times, 1 ms to 30 s 16 times, 10 ms to 5 min 236 times, 100 ms to 54 min | Data areas and their retentive characteristics | | | | | | | Flags | | | | | | | | 32 Byte | 32 Byte | 32 Byte | 32 Byte | 32 Byte | 32 Byte | | Yes; M0.0 to M31.7 | Yes; M0.0 to M31.7 | Yes; M0.0 to M31.7 | Yes; M0.0 to M31.7 | Yes; M0.0 to M31.7 | Yes; M0.0 to M31.7 | - of which retentive with battery
| 0 to 255, via super capacitor or battery, adjustable | 0 to 255, via super capacitor or battery, adjustable | 0 to 255, via super capacitor or battery, adjustable | 0 to 255, via super capacitor or battery, adjustable | 0 to 255, via super capacitor or battery, adjustable | 0 to 255, via super capacitor or battery, adjustable | - of which retentive without battery
| 0 to 112 in EEPROM, adjustable | 0 to 112 in EEPROM, adjustable | 0 to 112 in EEPROM, adjustable | 0 to 112 in EEPROM, adjustable | 0 to 112 in EEPROM, adjustable | 0 to 112 in EEPROM, adjustable | Configuration | | | | | | | - Connectable programming devices/PCs
| SIMATIC PG/PC, Standard PC | SIMATIC PG/PC, Standard PC | SIMATIC PG/PC, Standard PC | SIMATIC PG/PC, Standard PC | SIMATIC PG/PC, Standard PC | SIMATIC PG/PC, Standard PC | - Central units/expansion units, max.
| 7 expansion modules. Only expansion modules of the S7-22x series can be used. (Because of the limited output current, the use of expansion modules may be subject to restrictions.) | 7 expansion modules. Only expansion modules of the S7-22x series can be used. (Because of the limited output current, the use of expansion modules may be subject to restrictions.) | 7 expansion modules. Only expansion modules of the S7-22x series can be used. (Because of the limited output current, the use of expansion modules may be subject to restrictions.) | 7 expansion modules. Only expansion modules of the S7-22x series can be used. (Because of the limited output current, the use of expansion modules may be subject to restrictions.) | 7 expansion modules. Only expansion modules of the S7-22x series can be used. (Because of the limited output current, the use of expansion modules may be subject to restrictions.) | 7 expansion modules. Only expansion modules of the S7-22x series can be used. (Because of the limited output current, the use of expansion modules may be subject to restrictions.) | I/O expansions | | | | | | | - Analog inputs/outputs, max.
| 35; max. 28 inputs and 7 outputs (EM) or max. 0 inputs and 14 outputs (EM) | 35; max. 28 inputs and 7 outputs (EM) or max. 0 inputs and 14 outputs (EM) | 38; 2 on board inputs and one output, in addition max. 28 inputs and 7 outputs (EM) or max. 0 inputs and 14 outputs (EM) | 38; 2 on board inputs and one output, in addition max. 28 inputs and 7 outputs (EM) or max. 0 inputs and 14 outputs (EM) | 35; max. 28 inputs and 7 outputs (EM) or max. 0 inputs and 14 outputs (EM) | 35; max. 28 inputs and 7 outputs (EM) or max. 0 inputs and 14 outputs (EM) | - Digital inputs/outputs, max.
| 168; max. 94 inputs and 74 outputs (CPU+EM) | 168; max. 94 inputs and 74 outputs (CPU+EM) | 168; max. 94 inputs and 74 outputs (CPU+EM) | 168; max. 94 inputs and 74 outputs (CPU+EM) | 148; max. 128 inputs and 120 outputs (CPU+EM) | 148; max. 128 inputs and 120 outputs (CPU+EM) | - AS interface inputs/outputs, max.
| 62; AS interface A/B slaves (CP 243-2) | 62; AS interface A/B slaves (CP 243-2) | 62; AS interface A/B slaves (CP 243-2) | 62; AS interface A/B slaves (CP 243-2) | 62; AS interface A/B slaves (CP 243-2) | 62; AS interface A/B slaves (CP 243-2) | Connection system | | | | | | | | Yes | Yes | Yes | Yes | Yes | Yes | 1st interface | | | | | | | | integrated RS 485 interface | integrated RS 485 interface | integrated RS 485 interface | integrated RS 485 interface | integrated RS 485 interface | integrated RS 485 interface | | RS 485 | RS 485 | RS 485 | RS 485 | RS 485 | RS 485 | Functionality | | | | | | | | Yes; as MPI Slave for data exchange with MPI Masters (S7-300/S7-400-CPUs, OPs, TDs, Push Button Panels); internal S7-200 CPU/CPU communication is limited in the MPI network; transmission rates 19.2/187.5 kbit/s | Yes; as MPI Slave for data exchange with MPI Masters (S7-300/S7-400-CPUs, OPs, TDs, Push Button Panels); internal S7-200 CPU/CPU communication is limited in the MPI network; transmission rates 19.2/187.5 kbit/s | Yes; as MPI Slave for data exchange with MPI Masters (S7-300/S7-400-CPUs, OPs, TDs, Push Button Panels); internal S7-200 CPU/CPU communication is limited in the MPI network; transmission rates 19.2/187.5 kbit/s | Yes; as MPI Slave for data exchange with MPI Masters (S7-300/S7-400-CPUs, OPs, TDs, Push Button Panels); internal S7-200 CPU/CPU communication is limited in the MPI network; transmission rates 19.2/187.5 kbit/s | Yes; as MPI Slave for data exchange with MPI Masters (S7-300/S7-400-CPUs, OPs, TDs, Push Button Panels); internal S7-200 CPU/CPU communication is limited in the MPI network; transmission rates 19.2/187.5 kbit/s | Yes; as MPI Slave for data exchange with MPI Masters (S7-300/S7-400-CPUs, OPs, TDs, Push Button Panels); internal S7-200 CPU/CPU communication is limited in the MPI network; transmission rates 19.2/187.5 kbit/s | | Yes; with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200 internal CPU/CPU communication; transmission rates 9.6/19.2/187.5 kbit/s | Yes; with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200 internal CPU/CPU communication; transmission rates 9.6/19.2/187.5 kbit/s | Yes; with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200 internal CPU/CPU communication; transmission rates 9.6/19.2/187.5 kbit/s | Yes; with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200 internal CPU/CPU communication; transmission rates 9.6/19.2/187.5 kbit/s | Yes; with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200 internal CPU/CPU communication; transmission rates 9.6/19.2/187.5 kbit/s | Yes; with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200 internal CPU/CPU communication; transmission rates 9.6/19.2/187.5 kbit/s | | Yes; as a freely programmable interface with an interrupt option for serial data transmission with external units with ASCII ptotocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4 kbit/s; at 1.2 to 38.4 kbit/s, the PC/PPI cable can be used as an RS232/RS485 converter | Yes; as a freely programmable interface with an interrupt option for serial data transmission with external units with ASCII ptotocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4 kbit/s; at 1.2 to 38.4 kbit/s, the PC/PPI cable can be used as an RS232/RS485 converter | Yes; as a freely programmable interface with an interrupt option for serial data transmission with external units with ASCII ptotocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4 kbit/s; at 1.2 to 38.4 kbit/s, the PC/PPI cable can be used as an RS232/RS485 converter | Yes; as a freely programmable interface with an interrupt option for serial data transmission with external units with ASCII ptotocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4 kbit/s; at 1.2 to 38.4 kbit/s, the PC/PPI cable can be used as an RS232/RS485 converter | Yes; as a freely programmable interface with an interrupt option for serial data transmission with external units with ASCII ptotocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4 kbit/s; at 1.2 to 38.4 kbit/s, the PC/PPI cable can be used as an RS232/RS485 converter | Yes; as a freely programmable interface with an interrupt option for serial data transmission with external units with ASCII ptotocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4 kbit/s; at 1.2 to 38.4 kbit/s, the PC/PPI cable can be used as an RS232/RS485 converter | MPI | | | | | | | | 187.5 kBit/s | 187.5 kBit/s | 187.5 kBit/s | 187.5 kBit/s | 187.5 kBit/s | 187.5 kBit/s | | 19.2 kBit/s | 19.2 kBit/s | 19.2 kBit/s | 19.2 kBit/s | 19.2 kBit/s | 19.2 kBit/s | 2nd interface | | | | | | | | | | integrated RS 485 interface | integrated RS 485 interface | integrated RS 485 interface | integrated RS 485 interface | | | | RS 485 | RS 485 | RS 485 | RS 485 | Functionality | | | | | | | | | | Yes; as MPI Slave for data exchange with MPI Masters (S7-300/S7-400-CPUs, OPs, TDs, Push Button Panels); internal S7-200 CPU/CPU communication is limited in the MPI network; transmission rates 19.2/187.5 kbit/s | Yes; as MPI Slave for data exchange with MPI Masters (S7-300/S7-400-CPUs, OPs, TDs, Push Button Panels); internal S7-200 CPU/CPU communication is limited in the MPI network; transmission rates 19.2/187.5 kbit/s | Yes; as MPI Slave for data exchange with MPI Masters (S7-300/S7-400-CPUs, OPs, TDs, Push Button Panels); internal S7-200 CPU/CPU communication is limited in the MPI network; transmission rates 19.2/187.5 kbit/s | Yes; as MPI Slave for data exchange with MPI Masters (S7-300/S7-400-CPUs, OPs, TDs, Push Button Panels); internal S7-200 CPU/CPU communication is limited in the MPI network; transmission rates 19.2/187.5 kbit/s | | | | Yes; with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200 internal CPU/CPU communication; transmission rates 9.6/19.2/187.5 kbit/s | Yes; with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200 internal CPU/CPU communication; transmission rates 9.6/19.2/187.5 kbit/s | Yes; with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200 internal CPU/CPU communication; transmission rates 9.6/19.2/187.5 kbit/s | Yes; with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200 internal CPU/CPU communication; transmission rates 9.6/19.2/187.5 kbit/s | | | | Yes; as a freely programmable interface with an interrupt option for serial data transmission with external units with ASCII ptotocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4 kbit/s; at 1.2 to 38.4 kbit/s, the PC/PPI cable can be used as an RS232/RS485 converter | Yes; as a freely programmable interface with an interrupt option for serial data transmission with external units with ASCII ptotocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4 kbit/s; at 1.2 to 38.4 kbit/s, the PC/PPI cable can be used as an RS232/RS485 converter | Yes; as a freely programmable interface with an interrupt option for serial data transmission with external units with ASCII ptotocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4 kbit/s; at 1.2 to 38.4 kbit/s, the PC/PPI cable can be used as an RS232/RS485 converter | Yes; as a freely programmable interface with an interrupt option for serial data transmission with external units with ASCII ptotocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4 kbit/s; at 1.2 to 38.4 kbit/s, the PC/PPI cable can be used as an RS232/RS485 converter | MPI | | | | | | | | | | 187.5 kBit/s | 187.5 kBit/s | 187.5 kBit/s | 187.5 kBit/s | | | | 19.2 kBit/s | 19.2 kBit/s | 19.2 kBit/s | 19.2 kBit/s | CPU/ programming | | | | | | | Programming language | | | | | | | | Yes | Yes | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Yes | Yes | | Bit logic instructions, compare instructions, timer instructions, counter instructions, clock instructions, integer math instructions, floating-point math instructions, numeric functions, move instructions, table instructions, logic instructions, shift and rotate instructions, conversion instructions, program control instructions, interrupt and communications instructions, logic stack instructions | Bit logic instructions, compare instructions, timer instructions, counter instructions, clock instructions, integer math instructions, floating-point math instructions, numeric functions, move instructions, table instructions, logic instructions, shift and rotate instructions, conversion instructions, program control instructions, interrupt and communications instructions, logic stack instructions | Bit logic instructions, compare instructions, timer instructions, counter instructions, clock instructions, integer math instructions, floating-point math instructions, numeric functions, move instructions, table instructions, logic instructions, shift and rotate instructions, conversion instructions, program control instructions, interrupt and communications instructions, logic stack instructions | Bit logic instructions, compare instructions, timer instructions, counter instructions, clock instructions, integer math instructions, floating-point math instructions, numeric functions, move instructions, table instructions, logic instructions, shift and rotate instructions, conversion instructions, program control instructions, interrupt and communications instructions, logic stack instructions | Bit logic instructions, compare instructions, timer instructions, counter instructions, clock instructions, integer math instructions, floating-point math instructions, numeric functions, move instructions, table instructions, logic instructions, shift and rotate instructions, conversion instructions, program control instructions, interrupt and communications instructions, logic stack instructions | Bit logic instructions, compare instructions, timer instructions, counter instructions, clock instructions, integer math instructions, floating-point math instructions, numeric functions, move instructions, table instructions, logic instructions, shift and rotate instructions, conversion instructions, program control instructions, interrupt and communications instructions, logic stack instructions | - User program protection/password protection
| Yes; 3-stage password protection | Yes; 3-stage password protection | Yes; 3-stage password protection | Yes; 3-stage password protection | Yes; 3-stage password protection | Yes; 3-stage password protection | | free cycle (OB 1), interrupt-driven, time-driven (1 to 255 ms) | free cycle (OB 1), interrupt-driven, time-driven (1 to 255 ms) | free cycle (OB 1), interrupt-driven, time-driven (1 to 255 ms) | free cycle (OB 1), interrupt-driven, time-driven (1 to 255 ms) | free cycle (OB 1), interrupt-driven, time-driven (1 to 255 ms) | free cycle (OB 1), interrupt-driven, time-driven (1 to 255 ms) | | 1 OB, 1 DB, 1 SDB subprograms with/without parameter transfer | 1 OB, 1 DB, 1 SDB subprograms with/without parameter transfer | 1 OB, 1 DB, 1 SDB subprograms with/without parameter transfer | 1 OB, 1 DB, 1 SDB subprograms with/without parameter transfer | 1 OB, 1 DB, 1 SDB subprograms with/without parameter transfer | 1 OB, 1 DB, 1 SDB subprograms with/without parameter transfer | - Number of sub-programs, max.
| 64 | 64 | 64 | 64 | 64 | 64 | Digital inputs | | | | | | | | 14 | 14 | 14 | 14 | 24 | 24 | Length of cable | | | | | | | - Length of cable shielded, max
| 500 m; Standard input: 500m, fast counters: 50m | 500 m; Standard input: 500m, fast counters: 50m | 500 m; Standard input: 500m, fast counters: 50m | 500 m; Standard input: 500m, fast counters: 50m | 500 m; Standard input: 500m, fast counters: 50m | 500 m; Standard input: 500m, fast counters: 50m | - Length of cable unshielded, max
| 300 m; not for high-speed signals | 300 m; not for high-speed signals | 300 m; not for high-speed signals | 300 m; not for high-speed signals | 300 m; not for high-speed signals | 300 m; not for high-speed signals | | Yes; optional, per group | Yes; optional, per group | Yes; optional, per group | Yes; optional, per group | Yes; optional, per group | Yes; optional, per group | Input voltage | | | | | | | | 24 V | 24 V | 24 V | 24 V | 24 V | 24 V | | 0 to 5 V | 0 to 5 V | 0 to 5 V; 0 to 1V (I0.3 to I0.5) | 0 to 5 V 0 to 1V (I0.3 to I0.5) | 0 to 5 V | 0 to 5 V | | min. 15 V | min. 15 V | min. 15 V; at least 4V (I0.3 to I0.5) | min. 15 V at least 4V (I0.3 to I0.5) | min. 15 V | min. 15 V | Input current | | | | | | | | 2.5 mA | 2.5 mA | 2.5 mA; 8 mA for I0.3 to I0.5 | 2.5 mA; 8 mA for I0.3 to I0.5 | 2.5 mA | 2.5 mA | Input delay (at rated value of the input voltage) | | | | | | | | | | | | | | | Yes; all | Yes; all | Yes; all | Yes; all | Yes; all | Yes; all | | 0.2 ms | 0.2 ms | 0.2 ms | 0.2 ms | 0.2 ms | 0.2 ms | | 12.8 ms | 12.8 ms | 12.8 ms | 12.8 ms | 12.8 ms | 12.8 ms | | | | | | | | | Yes; I0.0 to I0.3 | Yes; I0.0 to I0.3 | Yes; I0.0 to I0.3 | Yes; I0.0 to I0.3 | Yes; I0.0 to I0.3 | Yes; I0.0 to I0.3 | - for counters/technological functions
| | | | | | | | Yes; (E0.0 to E1.5) 30 kHz | Yes; (E0.0 to E1.5) 30 kHz | Yes; (E0.0 to E1.5) up to 200 kHz | Yes; (E0.0 to E1.5) up to 200 kHz | Yes; (E0.0 to E1.5) 30 kHz | Yes; (E0.0 to E1.5) 30 kHz | Digital outputs | | | | | | | - Number of digital outputs
| 10; Transistor | 10; Relay | 10; Transistor | 10; Relay | 16; Transistor | 16; Relay | - Length of cable shielded, max.
| 500 m | 500 m | 500 m | 500 m | 500 m | 500 m | - Length of cable unshielded, max.
| 150 m | 150 m | 150 m | 150 m | 150 m | 150 m | - Short-circuit protection of the output
| No; provided externally | No; provided externally | No; provided externally | No; provided externally | No; provided externally | No; provided externally | - Limitation of voltage induced on circuit interruption to
| 1 W | | 1 W | | 1 W | | Switching capacity of the outputs | | | | | | | | 0.75 A | 2 A | 0.75 A | 2 A | 0.75 A | 2 A | | 5 W | 200 W; 30 W DC, 200 W AC | 5 W | 200 W; 30 W DC, 200 W AC | 5 W | 200 W; 30 W DC, 200 W AC | Output voltage | | | | | | | | 20 V DC | L+/L1 | L+ minus 0.4V (5V/20,4V for A0.0 to A0.4; 20,4V A0.5 to A1.1) | L+/L1 | 20 V DC | L+/L1 | Output current | | | | | | | | 750 mA | 2 A | 750 mA | 2 A | 750 mA | 2 A | - for 0 signal residual current, max.
| 10 μA | 0 mA | 10 μA | 0 mA | 10 μA | 0 mA | Output delay at resistive load | | | | | | | | 15 µs; of the standard outputs, max. (A0.2 to A1.1) 2 µs; of the pulse outputs, max. (A0.0 to A0.1) 2 µs | 10 ms; all outputs | 15 µs; of the standard outputs, max. (A0.2 to A1.1) 15 µs; of the pulse outputs, max. (A0.0 to A0.1) 0.5 µs | 10 ms; all outputs | 15 µs; of the standard outputs, max. (A0.2 to A1.1) 2 µs; of the pulse outputs, max. (A0.0 to A0.1) 2 µs | 10 ms; all outputs | | 130 µs; of the standard outputs, max. (A0.2 to A1.1) 10 µs; of the pulse outputs, max. (A0.0 to A0.1) 10 µs | 10 ms; all outputs | 130 µs; of the standard outputs, max. (A0.2 to A1.1) 130 µs; of the pulse outputs, max. (A0.0 to A0.1) 1.5 µs | 10 ms; all outputs | 130 µs; of the standard outputs, max. (A0.2 to A1.1) 10 µs; of the pulse outputs, max. (A0.0 to A0.1) 10 µs | 10 ms; all outputs | Parallel switching of 2 outputs | | | | | | | | Yes | No | Yes | No | Yes | No | Switching frequency | | | | | | | - of pulse outputs, at resistive load, max.
| 20 kHz; A0.0 to A0.1 | 1 Hz | 100 kHz; A0.0 to A0.1 | 1 Hz | 20 kHz; A0.0 to A0.1 | 1 kHz | Summation current of the outputs (per group) | | | | | | | | 6 A | 10 A | 3.75 A | 10 A | 6 A | 10 A | - horizontal installation, up to 55 °C, max.
| 6 A | 10 A | 3.75 A | 10 A | 6 A | 10 A | Relay outputs | | | | | | | - Number of operating cycles
| | 10,000,000; mechanical 10 million, at rated load voltage 100,000 | | 10,000,000; mechanical 10 million, at rated load voltage 100,000 | | 10,000,000; mechanical 10 million, at rated load voltage 100,000 | Analog inputs | | | | | | | - Number of analog potentiometers
| 2; Analog potentiometer; resolution 8 bits | 2; Analog potentiometer; resolution 8 bits | 2; Analog potentiometer; resolution 8 bits | 2; Analog potentiometer; resolution 8 bits | 2; Analog potentiometer; resolution 8 bits | 2; Analog potentiometer; resolution 8 bits | Sensor supply | | | | | | | 24 V - sensor supply | | | | | | | | Yes; permissible range: 15.4 to 28.8 V | Yes; permissible range: 20.4 to 28.8 V | Yes; permissible range: 15.4 to 28.8 V | Yes; permissible range: 20.4 to 28.8 V | Yes; permissible range: 15.4 to 28.8 V | Yes; permissible range: 20.4 to 28.8 V | | Yes; electronic at 280 mA | Yes; electronic at 280 mA | Yes; electronic at 280 mA | Yes; electronic at 280 mA | Yes; electronic at 400 mA | Yes; electronic at 400mA | | 280 mA | 280 mA | 280 mA | 280 mA | 400 mA | 400 mA | Sensor | | | | | | | Connectable encoders | | | | | | | | Yes | Yes | Yes | Yes | Yes | Yes | - permissible closed-circuit current (2-wire BEROS), max.
| 1 mA | 1 mA | 1 mA | 1 mA | 1 mA | 1 mA | Integral functions | | | | | | | | 6; fast counters (each 30 kHz), 32 bits (incl. sign), usable as up/down counter or for connecting 4 incremental encoders with 2 pulse trains offset by 90° (max. 20 kHz (A/B counter)); parameterizable enable and reset input; interrupt options (incl. Call up a sub-program with any content) when the setpoint value is reached; change of count direction etc. | 6; fast counters (each 30 kHz), 32 bits (incl. sign), usable as up/down counter or for connecting 4 incremental encoders with 2 pulse trains offset by 90° (max. 20 kHz (A/B counter)); parameterizable enable and reset input; interrupt options (incl. Call up a sub-program with any content) when the setpoint value is reached; change of count direction etc. | 6; fast counters (2 to 200 kHz and 4 to 30 kHz), 32 bits (incl. sign), usable as up/down counter or for connecting 2 incremental encoders with 2 pulse trains offset by 90° (max. 1 to 100 kHz and 3 to 20 kHz (A/B counter)); parameterizable enable and reset input; interrupt options (incl. Call up a sub-program with any content) when the setpoint value is reached; change of count direction etc. | 6; fast counters (2 to 200 kHz and 4 to 30 kHz), 32 bits (incl. sign), usable as up/down counter or for connecting 2 incremental encoders with 2 pulse trains offset by 90° (max. 1 to 100 kHz and 3 to 20 kHz (A/B counter)); parameterizable enable and reset input; interrupt options (incl. Call up a sub-program with any content) when the setpoint value is reached; change of count direction etc. | 6; fast counters (each 30 kHz), 32 bits (incl. sign), usable as up/down counter or for connecting 4 incremental encoders with 2 pulse trains offset by 90° (max. 20 kHz (A/B counter)); parameterizable enable and reset input; interrupt options (incl. Call up a sub-program with any content) when the setpoint value is reached; change of count direction etc. | 6; fast counters (each 30 kHz), 32 bits (incl. sign), usable as up/down counter or for connecting 4 incremental encoders with 2 pulse trains offset by 90° (max. 20 kHz (A/B counter)); parameterizable enable and reset input; interrupt options (incl. Call up a sub-program with any content) when the setpoint value is reached; change of count direction etc. | - Count frequency (counters) max.
| 30 kHz | 30 kHz | 200 kHz | 200 kHz | 30 kHz | 30 kHz | | 4; 4 rising edges and/or 4 falling edges | 4; 4 rising edges and/or 4 falling edges | 4; 4 rising edges and/or 4 falling edges | 4; 4 rising edges and/or 4 falling edges | 4; 4 rising edges and/or 4 falling edges | 4; 4 rising edges and/or 4 falling edges | | 2; fast outputs, 20 kHz, with interrupt option; pulse width and frequency modulation | 2; fast outputs, 20 kHz, with interrupt option; pulse width and frequency modulation | 2; fast outputs, 20 kHz, with interrupt option; pulse width and frequency modulation | 2; fast outputs, 20 kHz, with interrupt option; pulse width and frequency modulation | 2; fast outputs, 20 kHz, with interrupt option; pulse width and frequency modulation | 2; fast outputs, 20 kHz, with interrupt option; pulse width and frequency modulation | - Cut-off frequency (pulse)
| 20 kHz | 20 kHz | 20 kHz | 20 kHz | 20 kHz | 20 kHz | Potentials/ electrical isolation | | | | | | | Digital output functions | | | | | | | | Yes; Optocoupler | Yes; Relay | Yes; Optocoupler | Yes; Relay | Yes; Optocoupler | Yes; Relay | - between the channels, in groups of
| 5 | 3, 3 and 4 | 5 | 3, 3 and 4 | 8 and 8 | 4, 5 and 7 | Digital input functions | | | | | | | | Yes | Yes | Yes | Yes | Yes | Yes; Optocoupler | - between the channels, in groups of
| 6 and 8 | 6 and 8 | 6 and 8 | 6 and 8 | 13 and 11 | 13 and 11 | Permissible potential difference | | | | | | | - between different circuits
| 500 V DC between 24 V DC and 5 V DC | 500 V DC between 24 V DC and 5 V DC; 1500 V AC between 24 V DC and 230 V AC | 500 V DC between 24 V DC and 5 V DC | 500 V DC between 24 V DC and 5 V DC; 1500 V AC between 24 V DC and 230 V AC | 500 V DC between 24 V DC and 5 V DC | 500 V DC between 24 V DC and 5 V DC; 1500 V AC between 24 V DC and 230 V AC | Environmental requirements | | | | | | | | For other ambient conditions: see "S7-200 Programmable Controller, System Manual" | For other ambient conditions: see "S7-200 Programmable Controller, System Manual" | For other ambient conditions: see "S7-200 Programmable Controller, System Manual" | For other ambient conditions: see "S7-200 Programmable Controller, System Manual" | For other ambient conditions: see "S7-200 Programmable Controller, System Manual" | For other ambient conditions: see "S7-200 Programmable Controller, System Manual" | Operating temperature | | | | | | | | 0 °C | 0 °C | 0 °C | 0 °C | 0 °C | 0 °C | | 45 °C | 45 °C | 45 °C | 45 °C | 45 °C | 45 °C | - horizontal mounting, min.
| 0 °C | 0 °C | 0 °C | 0 °C | 0 °C | 0 °C | - horizontal mounting, max.
| 55 °C | 55 °C | 55 °C | 55 °C | 55 °C | 55 °C | Air pressure | | | | | | | | 860 hPa | 860 hPa | 860 hPa | 860 hPa | 860 hPa | 860 hPa | | 1,080 hPa | 1,080 hPa | 1,080 hPa | 1,080 hPa | 1,080 hPa | 1,080 hPa | Relative humidity | | | | | | | | 5 % | 5 % | 5 % | 5 % | 5 % | 5 % | | 95 %; RH stressing level 2 in accordance with IEC 1131-2 | 95 %; RH stressing level 2 in accordance with IEC 1131-2 | 95 %; RH stressing level 2 in accordance with IEC 1131-2 | 95 %; RH stressing level 2 in accordance with IEC 1131-2 | 95 %; RH stressing level 2 in accordance with IEC 1131-2 | 95 %; RH stressing level 2 in accordance with IEC 1131-2 | Degree of protection and class of protection | | | | | | | | Yes | Yes | Yes | Yes | Yes | Yes | Dimensions and weight | | | | | | | | 360 g | 410 g | 390 g | 440 g | 550 g | 660 g | | 120.5 mm | 120.5 mm | 140 mm | 140 mm | 196 mm | 196 mm | | 80 mm | 80 mm | 80 mm | 80 mm | 80 mm | 80 mm | | 62 mm | 62 mm | 62 mm | 62 mm | 62 mm | 62 mm | |