0

Разделы

LA 724i силовой модуль - LA 724 силовые модули

LA 724i силовой модуль - LA 724 силовые модули

The LA 724 is the universal power output module with a maximum power of 1000 W per channel with 24 channels.

Дизайн

  • Connection of heat emitter via front plug
  • Channel fuses at front
  • Heat dissipation possible using optional LM 724 fan module

Функции

Output power

  • 24 power channels with 230 V (8 outputs each per phase)
  • Max. 1000 W switching capacity per output
  • Max. 7360 W switching capacity per phase
  • Power triacs with zero crossover switching
  • Protection of triacs and opto-triacs against overvoltages by Transil diodes

Forced ventilation

Depending on the switching capacity and ambient temperature, the power output may have to be forced ventilated. An LM 724 fan module is available as an optional accessory.
Detailed information is available in the manual.

Temperature monitoring

An NTC thermistor is present on the heat sink to monitor its temperature. This temperature-dependent resistor outputs a signal to the S7-300 at 92 °C ± 3 °C. A second switching threshold at 100 °C ± 3 °C switches off the power outputs of the module.

Fuses

Each channel of the LA 724i has an externally-accessible 5-A fuse to protect the power triac and a 32-A fuse per phase to limit the phase current.

Diagnostics facilities

Diagnostics functions are provided as standard to detect the following faults:

  • Internal fuse blown or triac at high-resistance
  • Triac failed
  • External fault such as blown fuse, heat emitter or cable breakage

If several heat emitters are connected to one output in parallel, failure of an individual heat emitter is detected by extended diagnostics.

Технические данные

LA 724i power output module

Outputs per power output (LA 724i)

24

Electrical isolation from control unit

By opto-triac and optocoupler specified according to VDE 0884

Insulation voltage

 
  • Opto-triac

5 kV

  • Optocoupler

5.3 kV

Electrical isolation between power outputs

No

Load voltage (for star connection)

 
  • Rated value

230 V AC

  • Permissible range

187 V ... 264 V (TN system)

  • Frequency

50 Hz/60 Hz (47 Hz ... 63 Hz)

Total current per phase and module

Max. 32 A

Current per busbar

Max. 120 A

Output voltage

Full waves or half-waves switched at zero crossover

Output current

 
  • Maximum value

5 A

  • Residual current

Max. 7 mA

Power loss

Typ. PV = 0.7 W/A x I + 0.18 W/A2 x I2
(I = control current in the channel)

Switching capacity (simultaneity 100 %)

Max. 1000 W per channel at 230 V

Note:
the total current per phase of 32 A must not be exceeded.
Min. 75 W per channel

Parallel connection of heat emitters to one channel

 
  • Quantity

Typ. 5

  • Minimum power per radiator

200 W

Total switching capacity per LA 724i (ambient temperature = 40 °C)

 
  • Without forced ventilation

14.4 kW

  • With forced ventilation

22 kW

Type of load

Resistive loads with max. 15 times the cold current in the 1st half-wave (if necessary, flash heat emitters can be measured at Siemens)

Overload

5 times the rated current for 20 ms

Thermal protection

Yes, by NTC thermistor
92 °C ± 3 °C: warning to host controller via PROFIBUS DP
100 °C ± 3 °C: switching off of power outputs

Short-circuit protection

One 5 A/250 V quick-blow fuse per output

Overvoltage protection

By Transil diodes

Connection line

R max = 14 W
(short-circuit protection is thus ensured)

Dimensions of LA 724
(W x H x D)

50 mm x 480 mm x 210 mm

Weight, approx.

5.3 kg


Дополнительно

Order No.

Description

6ES7 171 ‑ 3AA00 ‑ 0AA0

Fan module for HS 724
Required with powers greater than 650 Watt per channel on LA 724 (for 2 power outputs)

Part No. 40018384

Phönix male connector, screw-type
(3 units required per LA)

6ES7 171 ‑ 2XX00 ‑ 6DA0

Heater controller busbar

Part No. 41760372

5 A fuse; fast-blow


Дальнейшая информация

Ordering location

New parts and accessories

Siemens AG A&D SE FTH

Org-ID 10001539

Repairs

Siemens AG A&D SE EWF RC Fürth

Org-ID AV000085

Returned items

Siemens AG A&D RC Service

Org-ID A4025956


Заказные данные

Заказной №ОписаниеВес (кг)ДоставкаМин. зак. (шт)
6BK1700-2BA00-0AA0LA 724I УПРАВЛЕНИЕ НАГРЕВОМ СИЛОВОЙ ВЫХОД НА ЦЕНТР. СХ. ZA 724I СТАНДАРТНАЯ ВЕРСИЯ 5.66 - 8 недель (C)1

Аксессуары

Заказной №ОписаниеВес (кг)ДоставкаМин. зак. (шт)
6ES7171-2XX00-6DA0УПРАВЛЕНИЕ НАГРЕВОМ-ТОКОВЫЕ ШИНЫ КАК ЗАП. ЧАСТЬ0.0226 - 8 недель (C)1
6ES7171-3AA00-0AA0МОДУЛЬ ВЕНТИЛЯТОРА ДЛЯ HS 724, ТРЕБУЕТСЯ ПРИ МОЩНОСТЯХ БОЛЬШЕ 1000 ВАТТ НА КАНАЛ НА LA7240.82по запросу (D)1