Для просмотра информации в формате PDF необходимо установить Adobe Acrobat Reader. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The magnetic voltage regulators with selectable input and output voltages can be found under the information button, the standard products under the ordering data. Please send your selection together with the Order No. stem and the desired options in clear text to MD_Anfrage@brmr.siemens.de/ or by fax to +49 (0)421/5125 333 You will receive a reply containing the complete Order No. so that you can place your order.
E-mail: MD_Anfrage@brmr.siemens.de (Germany)
E-mail: MD_inquiry@brmr.siemens.de (Europe/World)
or by fax: +49 (0)421/5125 333 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Область примененияThe 4FK magnetic voltage regulators are used for consumers which are supplied with AC voltage and respond very strongly to voltage fluctuations. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
ДизайнThe settling time for the voltage regulators is about 40 ms. However, they can only bridge mains supply interruptions of up to a half-wave. The stabilizing effect is based on a tuned anti-resonant circuit with a saturated iron-core reactor (see "Circuit diagrams“). This saturated iron-core reactor is responsible for the distorted output voltage (harmonic distortion of 3 % to 4 %). Due to the anti-resonant circuit, magnetic voltage regulators are frequency-dependent. Voltage regulators are designed and harmonized for ohmic loads. If the consumer has a power factor outside the specification, the output voltage is decreased for an inductive load and increased for a capacitive load. Inductive loads can be compensated with corresponding compensation capacitors. It is also possible to construct voltage regulators which are adapted to a different power factor. The outputs of magnetic voltage regulators are short-circuit-proof i.e. if the output is short-circuited the current increases between 1.3 and 1.5 times the basic value. The input current changes only slightly. Due to this, a voltage regulator cannot trigger a fuse. The consumer can be protected by a motor protection contactor on the output which is set to the rated current. Due to the high induction in the iron core, the magnetic voltage regulators have inrush currents which are between 10 and 30 times higher than the rated current. For this reason, a time-lag mains fuse must be fitted to the input. The characteristics of magnetic voltage regulators can be summarized as follows:
Please note that the operating temperature and the noise generated for a magnetic voltage regulator is higher than for an isolating transformer. Ambient conditionsThe 4FK magnetic voltage regulators are climate-proof for mounting in rooms with an internal climate to DIN 50010. Limit values:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Характеристика
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Схема подключения [PDF]Для просмотра информации в формате PDF необходимо установить Adobe Acrobat Reader. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Схема подключения | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Заказные данные
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||