Дальнейшая информация Description | 7MB2021 | 7MB2011 | 7MB2011 Ex | 2 years (Stück) | 5 years (Stück) | Order No. | Analyzer section | | | | | | | O-ring (stub) | x | x | x | 2 | 4 | C71121-Z100-A159 | O-ring | x | | | 1 | 2 | C74121-Z100-A6 | O-ring (measuring head) | x | x | x | 2 | 4 | C79121-Z100-A32 | Spacer | x | x | x | - | 1 | C79451-A3277-B22 | Sample cell, SS, type No. 1.4571, non-flow type compensation circuit | x | x | x | - | 1 | C79451-A3277-B535 | Sample cell, tantalum, non-flow type compensation circuit | x | x | x | - | 1 | C79451-A3277-B536 | Sample cell, SS, type No. 1.4571, flow type compensation circuit | x | x | x | - | 1 | C79451-A3277-B537 | Sample cell, tantalum, flow type compensation circuit | x | x | x | - | 1 | C79451-A3277-B538 | Measuring head, non-flow type compensation circuit | x | x | x | 1 | 1 | C79451-A3460-B525 | Measuring head, flow type compensation circuit | x | x | x | 1 | 1 | C79451-A3460-B526 | Magnetic connection plate | x | x | x | - | 1 | C79451-A3474-B606 | Temperature sensor | x | x | x | - | 1 | C79451-A3480-B25 | Heating inset | x | x | x | - | 1 | W75083-A1004-F120 | Sample gas path | | | | | | | Pressure switch (sample gas) | x | | | 1 | 2 | C79302-Z1210-A2 | Flowmeter (version with pump only) | x | | | 1 | 2 | C79402-Z560-T1 | Restriction, SS type No. 1.4571, gas path hose | x | | | 2 | 2 | C79451-A3480-C10 | Restriction, titanium, gas path pipe | x | x | x | 2 | 2 | C79451-A3480-C37 | Reference gas path, 3000 hPa | x | x | x | 1 | 1 | C79451-A3480-D518 | Capillary tube, 100 hPa, connection kit | x | x | x | 1 | 1 | C79451-A3480-D519 | Restriction, SS type No. 1.4571, gas path pipe | x | x | x | 1 | 1 | C79451-A3250-C5 | Electronic | | | | | | | Temperature controller - electronic, 230 V AC | | x | x | - | 1 | A5E00118527 | Temperature controller - electronic, 115V AC | | x | x | - | 1 | A5E00118530 | Fuse (unit fuse) | | | x | 1 | 2 | A5E00061501 | Front panel with keyboard | x | | | 1 | 1 | C79165-A3042-B505 | Temperature controller | x | x | x | - | 1 | C79451-A3474-B56 | Base plate, without firmware | x | x | x | - | 1 | C79451-A3474-B601 | Adapter board, LCD/keyboard | x | x | | 1 | 1 | C79451-A3474-B605 | LC display | x | x | | 1 | 1 | W75025-B5001-B1 | Connector filter | x | x | x | - | 1 | W75041-E5602-K2 | Temperature fuse (heated version only) | | x | | - | 1 | W75054-T1001-A150 | Fuse, T 0.63/250 V | x | x | x | 2 | 4 | W75054-L1010-T630 | Fuse, 1 A, 110/220 V | x | x | x | 2 | 4 | W75054-L1011-T100 | Fuse, 2.5 A, 250 V | | x | x | 2 | 3 | W75054-L1011-T250 | If the OXYMAT 6 was delivered with specially cleaned gas path for high oxygen content (so-called „Cleaned for O2 service“), please absolutely specify it for a spare part order. This is the only way to guarantee that the gas path furthermore corresponds to the special requirements for this variant. |